null
Loading…
Skip to main content Skip to buy box

Holiday gifts by Fri, Dec 18? Order by Thu, Dec 3. Plan gifts Gifts by Dec 18? Order by Dec 3. Plan

Free shipping on most orders over $95 in the contiguous US

Specialists Mon–Fri, 8:30 am–5 pm PTSpecialists Mon–Fri, 8:30–5 PT866-522-6657

Printed to order
Third Harmonic Utilization in Permanent Magnet Machines book cover by Kai Wang, Zi-Qiang Zhu
Hardcover

Third Harmonic Utilization in Permanent Magnet Machines

by Kai Wang and Zi-Qiang Zhu

From $96.79 / copy at 25+ copies; lower per-copy prices at higher quantities (see Volume pricing) As low as $94.59 at 100+

Total $2,419.75

Hardcover · 211 pages Springer Nature Singapore · 2018

Format

Hardcover
Volume pricing

The more copies, the less each one costs

Applied automatically in your cart. No code needed.

More than a box of books

Turn this order into a program

Groups that order together often pair the copies with something more. We handle the extras so you don't have to.

About the book

Third Harmonic Utilization in Permanent Magnet Machines

This book investigates the utilization of harmonics in the permanent magnet (PM) or rotor shape to improve the torque density of PM brushless AC machines including three-phase inner rotor and outer rotor machines, five-phase machines, dual three-phase machines, linear machines, by means of analytical, finite element analyses, and as well as experimental validation. 

The torque density can be improved while the torque ripple remains low in PM shaping utilizing the 3rd harmonic. In this book, the analytical expression of output torque is derived for PM machines with rotor shape using the 3rd harmonic, and then the optimal 3rd harmonic for maximizing torque is analytically obtained. 

The book compares the PM shape in surface-mounted PM (SPM) machines and the rotor lamination shape in interior PM (IPM) machines utilizing the 3rd harmonic, and it becomes clear that their shaping methods and amount of torque improvement are different. 

In a five-phase PM machine, the 3rd harmonic can be utilized in both the current waveform and PM shapes to further improve the output torque. For the dual three-phase SPM machines without deteriorating the torque more than 30% when the optimal 3rd harmonic into both the current and PM shape are injected.

The harmonics in airgap flux density have significant influence on the cogging torque, stator iron flux distribution, and radial force between the rotor and stator. These effects has been investigated as well in this book.



Details

Publisher
Springer Nature Singapore
Authors
Kai Wang, Zi-Qiang Zhu
Format
Hardcover
Published
Sep 17, 2018
ISBN-13
9789811306280
Pages
211
Printing
Printed on demand
Buying for a group

Third Harmonic Utilization in Permanent Magnet Machines for groups: pricing

Volume pricing applies automatically in your cart. No codes, no account needed.

CopiesPrice per copyYou save
25 – 49 $96.79 12% off list
50 – 99 $95.69 13% off list
100+ $94.59 14% off list
Ways groups use it

Popular for

1
Book clubs

A copy for every member, on one order.

2
Events and conferences

A book for every attendee, delivered to your venue.

3
Gifts

For clients, staff, members or volunteers.

Where can I buy 100 copies of Third Harmonic Utilization in Permanent Magnet Machines?

BookPal sells Third Harmonic Utilization in Permanent Magnet Machines in quantity. At 100 copies the price is $94.59 a copy, against a list price of $109.99, and the cart applies the volume tier automatically. Free shipping on most orders over $95 in the contiguous US. A specialist can quote a larger or mixed order.

  • New books only, straight from the publisher
  • Volume prices apply automatically in the cart, with no code needed
  • Order at least 10 business days before you need the books (11 from mid-November through December)

Ask a specialist about a larger or mixed order

What does Third Harmonic Utilization in Permanent Magnet Machines cost when I buy for a group?

Volume pricing applies automatically in your cart, with no code needed. Price per copy: 25 to 49 copies, $96.79 (12% off list); 50 to 99 copies, $95.69 (13% off list); 100+ copies, $94.59 (14% off list). Need a different quantity, or a quote to forward for approval? Ask a specialist and we will confirm pricing before you pay.

How fast can I get copies of Third Harmonic Utilization in Permanent Magnet Machines?

This title is printed on demand, so it needs production time before it ships. Need them by a specific date? Request a quote and we'll confirm timing before you pay.

Can you ship to several locations or people's homes?

Yes. We ship group orders to one address, to multiple sites, or to individual recipients, in the US and internationally. See fulfillment options.

Can I get a formal quote for approval before ordering?

Yes. Request a quote and we'll send a PDF you can forward for approval.

Do you accept purchase orders and tax-exempt orders?

Yes. We accept purchase orders upon approval, as well as cards, PayPal, ACH, wire transfers and checks. BookPal is a tax-exempt supplier in all 50 states. See purchase orders and sales tax exemption.

What if I find a lower price?

Send us the link. We match prices from other booksellers and distributors on a new copy in the same edition, available to ship in the quantity you need. Clearance sales and pricing errors are the exception, and we'll tell you quickly if that's the case. Start a price match.

Log In
Review Your Cart
Your cart is empty Your cart is empty Your cart is empty

Menu

Recently Viewed Recently Viewed
Back to top Back to top